Probe selection guide for PosiTector 6000 thickness gauge

The PosiTector 6000 thickness gauge consists of a measurement box to which a probe will be connected.

There are different types of interchangeable probes:

  • PosiTector 6000 probes: probes for measuring the thickness of coatings on metal supports.
  • PosiTector 200 probes: coating thickness measurement probes on non-metallic supports.
  • PosiTector UTG probes: material thickness measurement probes (wall thickness)
  • PosiTector SPG probes: profile depth measurement probes
  • PosiTector RTR probes: Press O film tape reading probes (testex tape)
  • PosiTector DPM probes: Temperature - Hygrometry - Dew Point measurement probes
  • PosiTector IRT probes: infrared temperature measurement probes
  • PosiTector SST probes: probes for measuring soluble salts according to the Bresle method
  • PosiTector SHD probes: Shore A or Shore D hardness measurement probes
  • PosiTector BHI probes: Barcol hardness measurement probes

There are two types of PosiTector box:

The common characteristics are:

  • Waterproof and durable housing with backlit LCD display.
  • Simple navigation menu in French.
  • Calibration possible in 1 or 2 points.
  • Continuous display of statistics (number of measurements, average, standard deviation, minimum and maximum value).
  • Data transfer via USB port with direct PC connection (html page) or by Posisoft software as a free download or by CloudTM connection
  • Supplied with nylon bag, shockproof protective case with belt clip, screen protection film, USB cable, 3 AAA batteries and user manual in French.
  • 2 years warranty.

- Standard housing (1):

  • Memory of 250 values in 1 single batch.
  • Warning: the standard box requires a transfer of measurements to a PC before any probe change.

- Advanced Box (3):

Real-time graphic display, insertion of photos.

  • Scan mode (continuous reading without raising the probe).
  • Memorization of different calibration adjustments depending on the media.
  • Customizable min / max limits.
  • Online help.
  • Memory of 100,000 measurements that can be divided into 1000 lots and renamed sub-lots.
  • Possibility to name and annotate the measures from the alphanumeric keyboard.
  • Data transfer by USB, Bluetooth or Wifi (PC, Smartphones or tablets or printer).
  • Automatic download of software updates.

Detail of the probes for the Positector 6000 thickness gauge

Coating thickness measurement probes on metal supports are available in

  • Remote probe (reference ending in S): The probe is connected to the PosiTector measurement box by a cable
  • Compact probe: The probe is directly connected to the device

The probes exist for

  • Measurement on ferrous support only (reference with an F)

These probes use magnetic induction technology and allow the measurement of non-magnetic coatings on a ferrous support (tinplate, steel, cast iron, etc.)

  • Measurement on non-ferrous support only (reference with an N)

These probes use eddy current technology and allow the measurement of non-conductive coatings on non-ferrous metal supports (aluminum, copper, titanium, etc.)

  • Measurement on all metals (reference with FN)

These probes combine the two technologies of magnetic induction and eddy current.

An FN probe will be a compact all-metal probe, an FNS probe will be a remote all-metal probe

A standard box + FNS probe = PosiTector 6000 FNS1

An advanced box + FNS probe = PosiTector 6000 FNS3

These different probes will be available in different geometry: standard, micro-probes, probes angled at 45 or 90 °, probes for extreme use ...

But also in different ranges of thicknesses ranging for example from 0 to 625 microns and ranging from 0 to 63 mm (see table below)

Summary table:

TABLEAU SONDES POSITECTOR 6000

Compact probes:

SONDES COMPACTES POSITECTOR 6000

Standard remote probes

SONDES DEPORTEES STANDARD POSITECTOR 6000

Extreme FXS Probe

Designed for extreme hot applications. The FXS Xtreme ™ probe features an improved zirconia reinforced alumina wear face and a new braided steel cable, making it ideal for harsh conditions and continuous measurement on hot surfaces up to 250 ° C ( 500 ° F).

SONDE FXS POUR POSITECTOR 6000

Standard dimensions 90 ° angled probes

Right angle probe for measuring in areas of low headroom. These constant pressure stainless steel probes are hermetically sealed to be completely waterproof - ideal for use underwater.

SONDES STANDARD COUDEES A 90 POUR POSITECTOR 6000

FNDS Duplex probe

The PosiTector 6000 FNDS probe measures individual thicknesses of paint and zinc coats in a duplex coating system with a single reading. Duplex coating systems use a combination of two corrosion protection systems - typically a paint or powder coating on galvanized steel (hot metallized, electro or zinc). The resulting corrosion protection is superior to either system of protection used independently. In duplex mode, the PosiTector 6000 FNDS simultaneously uses the magnetic (ferrous) and eddy-current (non-ferrous) principles to calculate and display individual paint and zinc coating thicknesses. The magnetic principle is used to measure the combined paint / zinc thickness on the ferrous substrate, and the eddy current principle is used to measure the paint thickness on the non-ferrous zinc coating. Zinc thickness is calculated by subtracting paint thickness from the combined paint / zinc thickness measurement.

SONDE FNDS Duplex pour POSITECTOR 6000

FNDS probe demonstration video:

vidéo de démonstration FNDS

Micro straight probes F0S or N0S:

With our smallest measuring tip and best thin film accuracy, this instrument is ideal for measuring on small parts, hard-to-reach areas or near edges. The straight F0S and N0S microprobes have a quick release adapter which makes them constant pressure probes for alignment on small flat or curved parts. This adapter is held in place by a spring. If the sleeve is not needed, simply remove it from the probe.

MICRO SONDES POUR POSITECTOR 6000.jpeg

Micro probes F45S or N45S angled at 45 °:

MICRO SONDES 45 POUR POSITECTOR 6000

Micro probes F90S or N90S angled at 90 °:

Micro sondes F90S ou N90S POUR POSITECTOR 6000

Long distance 90 ° angled micro probe:

Extended right angle probe (350mm / 13.75 ") for measuring in areas of low headroom.

sonde F90ES POUR POSITECTOR 6000

High thickness probes:

FT, FTS, FTRS, FNTS : Ideal for thick protective coatings such as epoxy, rubber, concrete coatings, intumescent fire retardant and more.

Sonde forte épaisseur

FKS, NKS : Premium probes Ideal for thick protective coatings such as epoxy, rubber, concrete coatings, intumescent flame retardant and more.

sondes forte épaisseur pour positector 6000

FHXS Xtreme : Measures non-conductive coatings on steel substrates. FHXS Xtreme ™ probe with alumina wear face and braided cable for hot or rough surfaces. Hot surfaces up to 250 ° C (500 ° F).

sonde fxhs

FJS : Ideal for measuring thick epoxies, rubbers, flame retardant and other thick protective coatings applied to steel. Lightweight, ergonomic design - 66% smaller than comparable probes The electromagnetic probe is less sensitive to the effects of roughness, curvature, material and alloy of the substrate

SONDE FJS

FLS:

Measures intumescent paint and other thick protective coatings on steel. Measures up to 38 mm (1.5 inches) Braided stainless steel cable - resistant to kinks, wear and cuts Includes hard case and 19 mm (750 mil) shim

Sonde FLS

FNGS :

Measures very thick coatings on ALL metals. Ideal for measuring ship hull coatings and thick intumescent paints. Measures up to 63.5 mm (2.5 inches) Measures non-conductive coatings on ferrous and non-ferrous metal substrates Braided stainless steel cable - resistant to kinks, wear and cuts Long life probe face and low wear for easy sweeping of large areas Includes handle for easy one-handed use Includes set of traceable coating thickness standards Includes instruction card

SONDE FNGS POUR POSITECTOR 6000