AMETEK BROOKFIELD
ASCOTT ANALYTICAL EQUIPMENT LTD
ATP ENGINEERING BV
BINDER GmbH
BUCKLEYS (UVRAL) LTD
COATMASTER
DAKOTA ULTRASONICS
DEFELSKO CORPORATION
FORMAT MESSTECHNIK GmbH
HACH LANGE
HANGON
HANNA INSTRUMENTS FRANCE
HILDEBRAND
KERN & SOHN GmbH
LABOMAT ESSOR
LAUDA
LENETA COMPANY
MITUTOYO FRANCE
Q-LAB CORPORATION
RHOPOINT INSTRUMENTS
RK PRINT COAT INSTRUMENTS Ltd
SIGMUND LINDNER GmbH
TABER INDUSTRIES
TAYLOR HOBSON LIMITED
TESTO
TQC BV
VEOLIA WATER STI
VERIVIDE
WALLACE
X-RITE EUROPE GMBH
The Novo-Gloss 20/60/85 ° glossmeter with simultaneous Haze measurement is designed to meet the measurement criteria of most gloss measurement applications.
Small, lightweight and durable, the glossmeter can be used in production and laboratory environments. The high specifications, including statistical analysis, graphical analysis and the software-free download function to PC, make it the ideal gloss meter for matt to medium surface finishes.
The Novo-Gloss 20/60/85 ° glossmeter with simultaneous Haze measurement is designed to meet the measurement criteria of most gloss measurement applications.
Small, lightweight and durable, the glossmeter can be used in production and laboratory environments. High specifications, including statistical analysis, graphical analysis and software-less download function to PC, make it the ideal gloss meter for matt to mirror surface finishes
ISO 2813 and ASTM D523 describe three angles for measuring gloss using a gloss meter.
Gloss is measured in gloss units (GU) and is traceable to reference standards held at NIST.
All gloss levels can be measured using the standard 60 ° measuring angle. It is used as a reference angle with the complementary angles of 85 ° and 20 ° often used respectively for low and high gloss levels.
The acute measuring angle of 20 ° improves the resolution of high gloss surfaces. Surfaces that measure 70GU and more at the standard 60 ° angle are often measured with this geometry.
The 20 ° angle is more sensitive to haze effects that affect the appearance of a surface.
For improved low gloss resolution, an 85 ° shave angle is used to measure the area. This angle is recommended for surfaces measuring less than 10 GU when measured at 60º.
This angle also has a larger measuring point that will average the differences in gloss of textured or slightly uneven surfaces.
Haze can best be described as an almost specular reflection. This effect is caused by a microscopic surface structure that slightly changes the direction of reflected light causing efflorescence adjacent to the specular angle (shine). The surface has a less reflective contrast and a shallow milky effect. In the coatings industry, this microscopic surface texture is often due to poorly dispersed raw materials, incompatible raw materials or oxidation and weathering.
For polished metal surfaces, haze is often associated with polish marks or chemical residue.
![]() | ![]() |
| Low Haze | High Haze |
![]() | ![]() |

Simultaneous measurement of all parameters, the results are time stamped.

Graphical reports for quick trend analysis.

Displays complete statistics for the number of reads in the current batch.

Good: bad parameters can be set for instant identification of nonconformities.

User definable batch names and batch sizes for faster and more efficient reporting.
Reference: Atmosfär
An advanced version of the CC -iP enclosures, Astmosfär enclosures have been designed to meet the even more demanding corrosion tests required in the automotive industry in particular.
Reference: SP0050
Imperfections or problems observed during coating inspections need to be clearly identified. A simple photo of the label makes it possible to identify the defect thanks to the comments area and its dimensions.
Download the software for your RHOPOINT INSTRUMENTS glossmeters here
Reference: Applicateur manuel K Lox
The Hand K Lox is a simple and economical steel cylinder applicator, mechanically engraved and chromed (anilox). It allows rapid flexographic proofs or varnish applications.
Software common to several devices offering multiple functionalities such as, without the present case, detailed analysis of the cooking process, oven and paint settings.
Adaptable to all Brookfield viscometers with classic geometry, the SSA (Small Sample Adapter) kit consists of a coaxial cylindrical mobile of your choice, a measuring chamber and a thermo-regulated double jacket by thermostatic bath.
Reference: Rhéomètre Brookfield RSO
Brookfield puts viscoelasticity measurements at your fingertips! The Quick Test functionality of the Brookfield RSO Rheometer allows testing within minutes. The RSO Stand-alone mode with easy-to-use interface makes it simple for QC Users, it can also help in Viscoelastic measurements by providing R&D users with advanced testing capabilities. RSO...
Reference: GP100
Very high quality proofing using rotogravure inks. Proofs are produced instantly using the GP100. Ideal for R&D, colorimetric databases, quality control and making presentation samples.
Robust and comfortable illuminating magnifier ideal for inspecting surfaces.
Reference: PosiTector 6000
Standard instruments in the industry, these simple, robust and precise thickness gauges use the principles of magnetic induction and eddy currents to measure coating thickness on ferrous and non-ferrous metals.
The Novo-Gloss 20/60/85 ° glossmeter with simultaneous Haze measurement is designed to meet the measurement criteria of most gloss measurement applications.
Small, lightweight and durable, the glossmeter can be used in production and laboratory environments. The high specifications, including statistical analysis, graphical analysis and the software-free download function to PC, make it the ideal gloss meter for matt to medium surface finishes.