Brookfield Maintenance and Calibration
Preventive and curative maintenance, calibration of Brookfield viscometers, rheometers and texturometers.
AMETEK BROOKFIELD
ASCOTT ANALYTICAL EQUIPMENT LTD
ATP ENGINEERING BV
BINDER GmbH
BUCKLEYS (UVRAL) LTD
COATMASTER
DAKOTA ULTRASONICS
DEFELSKO CORPORATION
FORMAT MESSTECHNIK GmbH
HACH LANGE
HANGON
HANNA INSTRUMENTS FRANCE
HILDEBRAND
KERN & SOHN GmbH
LABOMAT ESSOR
LAUDA
LENETA COMPANY
MITUTOYO FRANCE
Q-LAB CORPORATION
RHOPOINT INSTRUMENTS
RK PRINT COAT INSTRUMENTS Ltd
SIGMUND LINDNER GmbH
TABER INDUSTRIES
TAYLOR HOBSON LIMITED
TESTO
TQC BV
VEOLIA WATER STI
VERIVIDE
WALLACE
X-RITE EUROPE GMBH
Do you have measurements that are no longer reproducible? Viscosities that seem aberrant to you? Your viscometer no longer seems to be functioning normally ...
Then perhaps it would be necessary to carry out some simple checks.
- Without mobile, manually turn the screw thread where the mobile is hooked up to 10 or 15% then release: the value of % must return to zero + -0.5 %
- Check that the mobile turns on itself without runout (tolerance 2 mm acceptable)
If these first two checks are positive, then you will be able to check the calibration of your Brookfield viscometer.
For this, you need a standard oil, a thermostatic bath allowing you to heat the oil with an accuracy of + -0.1 ° C (Typically standard oils are certified at 25 ° C + -0.1 ° C) and a certified thermometer.
Then follow the calibration procedure indicated in the appendix of your user manual or by visiting our viscosity FAQs in which we explain how to check the calibration of your viscometer.
If you do not have the necessary means for this calibration check or if you notice that the viscometer is out of tolerance, then preventive maintenance and calibration should be carried out by Labomat Essor.
Labomat Essor is Brookfield's exclusive representative for France and has extensive experience in the sale, training, maintenance and calibration of Brookfield viscometers and rheometers.
Each year, our teams of technicians maintain and calibrate thousands of Brookfield viscometers and rheometers.
Our Brookfield maintenance and calibration services can be performed in the workshop or on site.
Preventive and curative maintenance, calibration of Brookfield viscometers, rheometers and texturometers.
How many hours in a Q-SUN Xenon Test Chamber or a QUV Weathering Tester equals a year of outdoor exposure?
How to take care of your coating thickness gauge?
How to clean spiral bars (Bar coaters, Meyer bars)?
Is Bubble Tower Temperature Calibration in Corrosion Testing Really Necessary ?
Case study: Automotive paint viscosity according to ASTM D7395
How to use a viscosity cup? How to convert flow time to viscosity in cSt?
Where can I get my Brookfield viscometer repaired or calibrated?