Reference: PosiTector 200
PosiTector 200 coating thickness gauges
Allow rapid and precise non-destructive measurement of the thickness of single or multi-layer coatings on all types of substrates such as wood, concrete, glass, plastic, etc.
AMETEK BROOKFIELD
ASCOTT ANALYTICAL EQUIPMENT LTD
ATP ENGINEERING BV
BINDER GmbH
BUCKLEYS (UVRAL) LTD
COATMASTER
DAKOTA ULTRASONICS
DEFELSKO CORPORATION
FORMAT MESSTECHNIK GmbH
HACH LANGE
HANGON
HANNA INSTRUMENTS FRANCE
HILDEBRAND
KERN & SOHN GmbH
LABOMAT ESSOR
LAUDA
LENETA COMPANY
MITUTOYO FRANCE
Q-LAB CORPORATION
RHOPOINT INSTRUMENTS
RK PRINT COAT INSTRUMENTS Ltd
SIGMUND LINDNER GmbH
TABER INDUSTRIES
TAYLOR HOBSON LIMITED
TESTO
TQC BV
VEOLIA WATER STI
VERIVIDE
WALLACE
X-RITE EUROPE GMBH
Measuring Total Coating Thickness on Plastics, Concrete, Wood & more Using Max Thick Mode on the PosiTector 200
Measuring Total Coating Thickness on Plastics, Concrete, Wood & more Using Max Thick Mode on the PosiTector 200
The PosiTector® 200 Coating Thickness Gage non-destructively measures coating thickness over non-metals including coatings over wood, concrete, plastic, composites and more using proven ultrasonic technology. With the new Max Thick Mode, the PosiTector 200 is easier than ever to use.

The PosiTector 200 probe emits an ultrasonic sound pulse that travels into the coating and reflects/echoes from any interface that is different in density, such as the substrate. It measures the time it takes for the sound pulse to travel from the probe to the coating/substrate interface and back. By multiplying this travel time by the velocity of sound through the coating (which is similar for most polymer coatings), the thickness of coating(s) can be calculated.
While there is almost always a density change at the coating-substrate interface that the PosiTector 200 can detect, density changes between coating layers can also be identified. PosiTector 200 Advanced models can often detect the interface between layers of different or identical coatings, as long as the initial layer is allowed to fully cure before application of the subsequent layer. Typically, the loudest ultrasonic echo represents the coating-substrate interface, with smaller echoes representing individual layer thicknesses.
The default measurement mode on the PosiTector 200 has been successfully utilized for decades to measure coating thickness on a wide variety of coatings and substrates. The PosiTector 200 searches for the loudest ultrasonic echo within its measurement range, and reports it as the coating thickness. In multi-layer mode, the thicknesses associated with the loudest echoes (depending on the number of layers selected) were reported as individual layer thicknesses. For most measurement applications, and particularly when measuring smooth, polymer coatings, this method provided accurate readings of the total coating thickness and individual layers, without any setup or adjustment required.
Applications with surface roughness or many loud echoes near the surface of the coating were sometimes challenging to measure with the PosiTector 200, because those conditions generated loud, unwanted echoes, often larger and louder than the desired echo form the coating-substrate interface. While increasing the instrument's Lo Range would ignore these unwanted echoes, it is time consuming and is sometimes difficult to make an adjustment that would ignore the unwanted surface echoes, while still measuring thinner areas of applied coating.
When increasing the Lo Range requires an adjustment too close to the expected coating thickness or if a user simply does not want to adjust the range, the NEW Max Thick Mode is optimal.
When Max Thick Mode is enabled, the PosiTector 200 searches for the deepest significant echo instead of the loudest echo. This means that any loud echoes near the surface (typically caused by surface roughness or a 'noisy' coating system) are ignored. This mode is often more effective at reporting the total coating thickness at the substrate interface, and eliminates the need to adjust the instrument's preset Lo Range. Since there will inevitably be some small echoes from within the substrate, only echoes above a pre-set loudness will be reported. On PosiTector 200 Advanced models, this threshold can be adjusted from the Graphic Display mode.
While Max Thick Mode is enabled and when multiple layers are selected (PosiTector 200 Advanced only), the layer thicknesses associated with the deepest ultrasonic echoes are reported.
Note: Max Thick Mode is not recommended for use with thin metal substrates or composites such as carbon fiber or fiberglass.
Conclusion
The PosiTector 200 Ultrasonic Coating Thickness Gage measures coating thickness on non-metals including wood, concrete, plastic and more. For most applications, the NEW Max Thick Mode will give the most accurate readings while eliminating the need to adjust the Lo Range to ignore incoming surface reflections.
A simple gage update adds this functionality to existing PosiTector Standard (serial numbers 795,375+) and Advanced (serial numbers 784,000+) models.
Reference: PosiTector 200
Allow rapid and precise non-destructive measurement of the thickness of single or multi-layer coatings on all types of substrates such as wood, concrete, glass, plastic, etc.
Thickness gauge : Calibration, Verification and Adjustment
Reference: PosiTector
The PosiTector box is a multifunction measuring device which is the ideal tool to support you in your various measurements. Compatible with many types of probes it will adapt to your needs. Connected, it is compatible with many software solutions on computer, tablet, smartphone, in the cloud or linked to third-party applications.
Probe selection guide for PosiTector 6000 thickness gauge
How to take care of your coating thickness gauge?
Measuring Paint Thickness on Plastic Bumpers/Fascias with Advanced Driver Assistance Systems (ADAS)
Measuring Total Coating Thickness on Plastics, Concrete, Wood & more Using Max Thick Mode on the PosiTector 200