Goniophotometer Rhopoint IQ 20°/60°/85°
The Rhopoint IQ quantifies surface quality issues that are invisible to a standard glossmeter and describes how light is reflected from a surface.
It simultaneously measures the following parameters:
- Gloss at 3 angles : 20/60/85°
- HAZE
- Reflected Image Quality (RIQ)
- Image sharpness (DOI)
- Rspec Gloss Specular Reflection: a measure proportional to the amount of light reflected from a surface measured at 20° (high gloss finishes), 60° (mid-gloss finishes), and 85° (matte finishes)
Haze: Reflection haze is scattered light caused by a micro-texture and is measured next to the main shine component. Symptoms - A milky finish is visible on high gloss coatings, halos may be visible around reflections from bright light sources. Causes (coatings) - Dispersion problems, incompatibilities of raw materials, improper drying or steaming. Causes (other) - Cleanliness, aging, oxidation, scratching, polishing.
RIQ: RIQ is used to quantify effects such as orange peel and surface ripple. This new setting gives higher resolution results compared to Image Distinction Measurement (DOI) and better mimics human perception of surface texture, especially on high quality finishes such as automobile. Symptoms of a bad RIQ: orange peel, brush marks, ripple, or other structures visible on the surface. Reflected images are distorted. Causes - Application problems, incorrect coating flow, coating viscosity too high/low, coating sag or flow before curing, incorrect particle size/distribution, excessive spraying, incorrect evaporation/recoat time, intercoat compatibility, incorrect curing time and curing temperature.
DOI: A measure of the clarity with which a reflected image will appear on a reflective surface.
RSPEC: The maximum brightness value at a very narrow angle.
Characteristics :
- Easy-to-read color display with adjustable brightness
- 6-button touchscreen interface
- Fully automatic calibration with tile detection and verification for error-free calibration
- Pocket instrument with integrated tile holder
- Pass/fail for easy identification of non conformities
- Full on-board statistics (max., min., average, standard deviation)
- Integrated trend analysis charts
- Grouping results with user-definable names
- Direct Data Entry via Bluetooth - This allows each reading to be instantly transmitted to any PC software such as Excel, Word, SPC programs, etc.
- Data transfer without software - USB download of results to PC without the need to install software
Technical specifications :
| Gloss |
RSPEC |
Haze |
QIR |
DOI |
| Measuring range : |
| 20º: 0-2000 GU |
0-2000 GU |
Quasi-specular reflectance measured at 17.2-19°, 21-22.8° |
0-100 |
0-100 |
| 60º: 0-1000 GU |
20° ± 0.09905° |
|
|
|
| 85º: 0-199 GU |
|
|
|
|
| Precision |
| Repeatability ± 0.2 GU • Reproducibility ± 0.5 GU (0-100 GU) |
|
Resolution 0.1 HU • Repeatability ± 0.5 HU • Reproducibility ± 1.5 HU |
Resolution 0.1 • Repeatability ± 0.2 • Reproducibility ± 0.5 |
Resolution 0.1 • Repeatability ± 0.2 • Reproducibility ± 0.5 |
| Resolution 0.1 GU • Repeatability ± 0.2 % • Reproducibility ± 0.5 % (100-2000 GU) |
|
|
|
|
| Standards |
| ISO 2813, ISO 7668 |
|
Standards ASTM E430, ISO 13803 |
|
Standard ASTM E430 |
| ASTM D523, ASTM D2457 |
|
|
|
|
| DIN 67530 |
|
|
|
|
| JIS 8741, JIS K 5600-4-7 |
|
|
|
|
Quick measurement of all parameters. Comprehensive integrated statistics with graphical trend analysis and reports.

Simultaneous measurement of all parameters, the results are time stamped.
Displays complete statistics for the number of reads in the current batch.

Graphical reports for quick trend analysis.

Pass / fail parameters can be set for instant identification of nonconformities